Electrolysis of Manganese Sulfate Solution - Cell Voltage, Power Efficiency and Power Consumption

First, the tank voltage
The tank voltage is the low voltage between adjacent anodes and anodes in the cell. It can be expressed by the actual voltage between each pair of cathode and anode. However, in the production practice, because the number of electrolytic cells is large, the number of anodes and cathodes is more, and the voltage drop between each pair of anodes and cathodes varies depending on the specific conditions, so the measurement method is not used, but The voltage drop of the total voltage-reduced conductive plate supplied to all series of electro-stacks is divided by the total number of slots on the series circuit, and the resulting high is the cell voltage, which is expressed as

Wherein V groove - groove voltage;
V 1 - the total voltage of all electrolytic cells connected in series;
V 2 - the voltage drop of the conductive plate;
N - the total number of electrolytic cells.
The voltage of an electrolytic cell consists of the theoretical decomposition voltage of electrolytic MnO 2 , the voltage drop of the electrolyte solution, and the voltage drop caused by the contact resistance of the wiring, the resistance of the plate, etc., expressed as V- groove = (φ + -φ - ) + IR liquid + IR pole + IR connection
Where (φ + -φ - ) - the polarization potential of the electrode, ie the theoretical decomposition voltage of the electrolytic MnO 2 ;
IR liquid - electric effluent resistance voltage drop;
IR pole - plate resistance voltage drop;
IR connection - contact resistance voltage drop.
Although ion-conducting electrolyte can rely on, but compared with the metal conductor, overcast much greater. When the current passes through the electrolyte, it will inevitably cause a pressure drop. Its magnitude is proportional to the current density, the distance between the yin and yang, and the resistivity of the electrolyte. It can be expressed by the following formula: V liquid = IR liquid = J · ρL
Where V liquid - electrolyte resistance voltage drop, V;
J——anode current density, A/m 2 ;
Ρ——resistance of electrolyte, Ω · m;
L——Yin and anode Liu distance, m.
It should be pointed out that industrial production inevitably has other ions (such as Mg 2+ , Ca 2+ , etc.), so the actual electrolyte voltage drop is larger than the above calculated value, generally between 0.4 and 0.6V. In order to reduce the power consumption, it is desirable to reduce the value of the V liquid . This requires lowering the current density and shortening the distance between the poles, but at the same time it is disadvantageous for improving current efficiency and strengthening production. Therefore, the electrolysis conditions must be reasonably determined.
Titanium anode plates and conductive heads have a certain resistance, which consumes a part of the voltage, generally around 0.2V. Or a copper cathode carbon rod and the conductive plate systems also have a certain resistance, also consumes a portion of a voltage of about 0.02V.
The cathode-anode contact tip also has a contact voltage drop at the contact point, which is about 0.03V. Since such contact electrical connectors are tens of thousands in industrial production, efforts to reduce the voltage drop at the contact point have important practical significance for saving electrical energy. In actual operation, it must be noted that each contact point conducts well.
The sum of the above four resistance voltage drops is the tank voltage of the electric forest. The cell voltage is also determined by the current density, the acidity and temperature of the electrolyte, and the distance between the electrodes, in addition to the contact resistance. Therefore, the way to reduce the cell voltage is to reduce the resistivity of the electrolyte, shorten the distance between the electrodes, and reduce the voltage loss at the contact point.
According to the test data of Mei Guanggui et al., the titanium material is used as the anode and the carbon rod is used as the cathode. The cell voltage of the electrolytic MnO 2 is generally 2.5~3.0V, and the purple Cu tube is used as the cathode, generally reducing the cell pressure by about 0.5V. The Ti-Mn alloy coating is used as the anode, and the anode sun is passivated to reduce the cell voltage by about 0.2V. [next]
Second, electrical energy efficiency
Electrical energy efficiency is the ratio of the amount of metal that is theoretically necessary to the amount of electricity actually produced in an electrolytic production process.

That is, electrical energy efficiency (η e ) = current efficiency (η i ) × voltage efficiency (η V )
In order to improve the efficiency of electric energy, in addition to improving the current efficiency, do not increase the voltage efficiency. The way is to reduce the electrolyte resistance, appropriately increase the temperature of the electrolyte, shorten the pole pitch to reduce the polarization of the electrode, and reduce the voltage of the tank.
Third, power consumption
Electrical energy efficiency represents the technical level of the electrowinning process. However, in production practice, it is rarely calculated as a regular indicator. In the factory practice, as the actual electric energy consumption that is often calculated, that is, the electric energy (kw · ht) consumed per ton of MnO 2 produced, expressed in W, the calculation formula is

Where I - the current through the electrolytic cell, A;
T——the time of electrolytic deposition, h;
N——the number of electrolytic cells;
q——Electrification equivalent of MnO 2 , 1.6216gA -1 · h - ;
V- groove - slot voltage, V;
η i - current efficiency, %;
W——Preparation of electricity consumption per ton of MnO 2 , kW · h.
According to industrial production data, the direct current consumption of electrolytic MnO 2 is generally 2000~2500kW · h/t.

Environmental Sanitation Equipment

As a leading supplier and manufacturer of environmental sanitation equipment in China, we specialize in providing a comprehensive range of waste management solutions. Our offerings include:
1. **Vehicle-Mounted Garbage Compression Equipment**: This equipment is designed to compact waste efficiently, making transportation more manageable and reducing the frequency of collection trips.
2. **Garbage Collection And Transportation Equipment**: We offer high-quality equipment that is reliable and durable, ensuring smooth waste collection and transportation processes.
3. **Supporting Garbage Bin Mobile Transfer Station**: Our mobile transfer stations provide flexibility in waste management, allowing for efficient waste transfer and reduction of odor and environmental impact in various settings.
We are committed to delivering low-priced, high-quality products tailored to the specific needs of our clients. We also provide customization options for our equipment to better serve various project requirements.
For more information or to discuss your specific needs, please feel free to contact us. We are here to assist you in finding the perfect waste management solution.

Environmental Sanitation Equipment,Vehicle-Mounted Garbage Compression Equipment,Garbage Collection And Transportation Equipment,Supporting Garbage Bin Mobile Transfer Station

Henan Lukewei Road Machinery Manufacturing Co.,Ltd , https://www.lkwmachinery.com

Posted on