The National Development and Reform Commission and the Ministry of Industry and Information Technology today announced that they will implement a ladder tariff policy for electrolytic aluminum enterprises. The AC power consumption of aluminum liquid electrolysis is not higher than 13700 kWh per ton, and the normal electricity price will be enforced; For 13700 kWh but not more than 13800 kWh, the price of electricity will be increased by 0.02 yuan per kilowatt-hour; if it is higher than 13800 kwh per ton, the price will be increased by 0.08 yuan per kilowatt-hour.
The notice stated that in order to implement the “Guiding Opinions of the State Council on Resolving the Contradiction of Serious Overcapacity†(Gufa [2013] No. 41), the electrolytic aluminum enterprises are accelerated to accelerate technological progress and reduce energy consumption. Recently, the National Development and Reform Commission, industry and information The Ministry of Chemical Industry issued the "Circular on Price-Effectiveness of Electrolytic Aluminum Enterprises Implementing a Stairway Electricity Price Policy" (Development and Reform Price [2013] No. 2530), and decided to implement the ladder power price policy for electrolytic aluminum enterprises starting from January 1, 2014.
The notice was clear, according to the actual level of electricity used by the electrolytic aluminum enterprises in the previous year, the sub-files determined the price of electricity. Aluminium liquid electrolysis AC power consumption is not higher than 13700 kwh per ton, normal electricity price is performed; above 13700 kWh per ton but not higher than 13800 kWh, electricity price increases by 0.02 yuan per kilowatt hour; higher than 13800 per ton For kWh, the electricity price increases by 0.08 yuan per kilowatt-hour.
The notice pointed out that all localities must standardize the direct electricity trading behavior of electrolytic aluminum enterprises and power generation enterprises. If the AC power consumption of aluminum liquid electrolysis is higher than 13700 kWh per ton or the target of energy saving assessment is not completed, direct power trading with the power company may not be conducted; if it is not higher than 13,350 kWh per ton, relevant departments of the provincial people's government shall give priority to supporting Participate in direct electricity trading.
The circular emphasized that all localities must not lower their own electricity prices for electrolytic aluminum enterprises, and those who have already implemented preferential tariffs should be corrected immediately. At the same time, it is necessary to strictly implement the relevant regulations on the collection of government funds, surcharges, and system reserve fees for the self-use electricity generated by the electrolyzed aluminum plant's self-produced power plants.
The notice requires that provincial-level price, industry, energy-saving competent authorities and power grid companies should work in close coordination according to the division of responsibilities, establish and improve relevant supporting systems, and jointly implement the ladder electricity pricing policy for electrolytic aluminum enterprises. At the same time, the implementation of step-by-step electricity price increases for electrolytic aluminum companies must be strictly managed and standardized.
The implementation of ladder electricity prices for electrolytic aluminum enterprises aims to use price levers to accelerate the elimination of backward electrolytic aluminum production capacity, reduce excessive consumption of resources, and promote structural adjustment of the electrolytic aluminum industry. In the next step, the National Development and Reform Commission will, together with relevant departments, timely promote in other industries in accordance with the national macro-control and industrial adjustment needs, promote industrial transformation and upgrading, and promote sustained and healthy economic development.
Characteristics
1. Rooftop packaged unit is single packaged type central Air Conditioning with its own cold source and air cooling. Factory assembled, tested and shipped complete with compressor, evaporator and condenser coils, fans and controls. They may be used for cooling only type, heat pump type, cooling only with electric heater type, constant temperature and humidity type etc.
2. The units are ideal for residential, commercial and industrial applications and are available in nominal cooling capacity from 10kW to 380kW/3TON to 100Ton.
3. Environment friendly refrigerant R407C, R410A and R134A.
4. It can be special design based on project needed, such as vertical type, stainless steel casing etc. Mainly used for office, commercial building, supermarket etc and easily installation and maintenance.
5. Operation range of outdoor temp. is from -10℃ to 45℃. And if T3 tropical design, the highest outdoor temperature could be 53 ℃.
6. Sturcture: Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents. Direct expansion coils with condensate drain tray.
7. Hermetic compressor: High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
8. Centrifugal fan: Forward curve centrifugal fans for air treatment section and axial fans for condensation section. Front, side and underside air discharge of the treasment unit. High external pressure, long air supply distance.
9. Electric panel: Electric panel consists of breaker and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.
Rooftop Packaged Unit,Rooftop Air Conditioner,Rooftop HVAC Units,Commercial Rooftop HVAC Units
Jinan Amrta Air Conditioning Co.,Ltd , http://www.waterchiller.pl