Temperature and humidity transmitters use temperature-humidity integrated probes as temperature measuring elements. They collect temperature and humidity signals, and are subjected to regulated voltage filtering, operation amplification, nonlinear correction, V/I conversion, constant current and reverse protection, etc. After the circuit is processed, it is converted into a current signal or a voltage signal output that is linearly related to temperature and humidity, and can also be output directly through the main control chip [1] for 485 or 232 interface [2]
Wall-mounted current type temperature and humidity transmitter
The current output temperature and humidity transmitter series is ideal for environmental applications such as libraries, archives, supermarkets, production plants, industrial automation, HVAC, pharmaceutical chemicals, telecommunication rooms, environmental monitoring, clean buildings, intelligent buildings, telecommunications base stations, etc. solution.
The use of a high-quality integrated digital humidity sensor as probe ensures excellent long-term stability, low hysteresis, and strong resistance to chemical contamination. The transmitter also features excellent repeatability and ease of use. , Integrated digital temperature and humidity sensor can be replaced quickly without calibration, and the cost is lower.
1 typical applicationMedical Chemical Communication Room HVAC HVAC
Environmental Monitoring Telecom Base Station Books and Archives
Clean building intelligent building supermarket, production workshop
automated industry
2 Features*Excellent value for money, suitable for different use environments
* Humidity, temperature output range user selectable
* Long-term stability, flexibility of use
* Easy to maintain, sensor probes can be replaced quickly without calibration
3 Technical parametersPower Supply 15-36VDC (RL<500Ω)
10-36VDC (RL<50Ω)
Relative humidity 0-100%RH
Humidity Sensor Humidity Capacitance
Humidity signal output 4-20mA (two-wire system)
Working range 0-100%RH
Accuracy ±2%RH(25°C) <±5%RH(-20-80°C)
Temperature Sensor
Temperature signal output
(Optional temperature measurement range):
0-50°C
-20-80°C
-40-60°C Current Output 4-20mA (Two Wires)
Accuracy ±0.2°C
Loss Current DC Supply Typical 4mA
Electrical connection terminal threaded joint maximum 1.5mm2
Shell / degree of protection ABS
Temperature Range Operating Temperature -40~80°C
Storage temperature -40~80°C
Specifications 100 X 80 X 30 mm 150g
Display parameters: using the highest standard display
Display Specifications: 45mm*35mm
Adaptable temperature range: -30~80 degrees Celsius
The range of viewing angles is 120 degrees horizontal and 120 degrees vertical.
Network temperature and humidity transmitter
The temperature and humidity integrated transmitter uses high-quality digital integrated sensors as probes, together with a reliable digital processing circuit, to convert the temperature and relative humidity in the environment into the corresponding standard analog signals, 4-20mA. Or 0-5V, it can reliably perform distributed monitoring with the host computer system. It has the characteristics of small size, light weight, wide range, high precision and fast response and long-term work stability, making it widely used in meteorology, national defense, scientific research, post and telecommunications, chemical industry, environmental protection, medicine, hotels, food and other materials Warehousing, HVAC, etc. Need to measure and control the temperature and humidity in the air.
4 Specifications4. Humidity accuracy: ±3%RH (25°C);
5. Working power supply: When load resistance ≤ Ω: 12 to 36V
LCD temperature and humidity transmitter
LCD temperature and humidity transmitter
250Ω<When load resistance ≤500Ω: 18 to 36V
(Maximum load resistance: ≤ 500Ω)
6. Overall size: 100×80×30mm
Temperature and humidity integration 4 to 20mA transmitter It can simultaneously change the temperature and humidity values ​​into current value changes, and can directly connect with various standard 4~20mA input secondary instrument.
5 outstanding featuresDigital calibration technology, high precision, good consistency
The power supply has no polarity intervention to avoid damage caused by wiring errors.
Standard two-wire mode, convenient wiring and compatibility
Digital calibration can be performed on-site with handheld instruments.
Reserved digital networking interface.
Note: (A and B must be connected correctly, otherwise the transmitter and the computer can not communicate properly. When long-distance transmission is required, it is recommended to use shielded twisted pair)
6 terminals and wiring definitionW2
W14. Send and receive data command format
* Host sender:
First byte Second byte Third byte Fourth byte Fifth byte Sixth byte
Device Address 0X03 0XA5 0XD2 CRCL CRCH
* Slave Receive Return:
First byte Second byte Third byte Fourth byte Fifth byte Sixth byte Seventh byte Eighth byte Ninth byte
Equipment Address 0X03 0X04 Humidity High Humidity Low Temperature High Temperature Low CRC Low CRC High
* Calculate the value of temperature and humidity: The value returned by the slave can be divided by 10. For example, if the humidity returned from the machine is 0x01, 0x52, then the value obtained by converting 0x0152 to decimal value is 338, and the value obtained with 338÷10 is the humidity value we need for 33.8 (%RH). The same applies to temperature. This is no longer mentioned.
Six, data collection and communication
1. Install <Temperature and Humidity Recorder> Software
2. Set the transmitter's address and baud rate, and use the RS232 to RS485 interface to connect the transmitter to the computer.
3. Open the installed software and follow the software instructions for the software
The address and baud rate are consistent with the transmitter's address and baud rate settings for data acquisition and communication.
7 common troubleshooting methodsThe transmitter does not show whether the power supply voltage is within the rated value; check the power cord is connected correctly
Can't communicate with the computer to check whether the RS485 signal line is connected correctly; whether the baud rate code on the PCB is set to match the software window
Colorimetric method: Determination of total ammonia and ammonium salt concentration in water samples (measured as nitrogen)
Test range: 0.20-0.40-0.60-0.90-1.20-1.50 mg/l
Temperature and humidity loggers
Temperature and humidity loggers
25 test times
Water Quality Quick Test Box - The water quality test expert fully embodies the basis for rapid analysis. Whether using visual colorimetry or titration, reliable results can be quickly obtained. Like a portable laboratory, routine water quality testing can be performed in real time. Can significantly save time and costs.
8 Product Featuresa. Easy to use - Visual colorimetry or titration is used to measure. The tester needs no training. Just follow the instructions.
b, fast and efficient - 2 to 10 minutes to complete a
The analysis of water samples is fast and efficient.
c, reliable results. ,
d, all reagents and accessories are built-in, no need to prepare.
e. Low cost of analysis. ,
f, small size, light weight, easy to carry.
g. Suitable for real-time water quality testing of sea and fresh water.
Applications: Water quality analysis is widely used in aquaculture, environmental analysis, wastewater discharge and treatment, industrial water, printing and dyeing, rinsing, chemicals and light industry, plating surface treatment, and swimming pools.
Features
1, the full-scale analog output linear good.
2, good consistency, long service life.
3, Wide range accuracy, good stability, small amount of annual drift.
4, fast response, low temperature coefficient.
5, good interchangeability
Working temperature: -20-60°C
Reaction time (ta) 5s
Humidity effective measurement range: 5-95 [%]
Humidity signal output corresponding range: 0-100 [%]
Humidity measurement: Under normal conditions, the drift is not greater than 1 [%]RH
Load capacity voltage type: ≥1KΩ, current type: 0-500Ω
Reference editing area
CATSU digging bucket is a type of Excavator Attachment that is used for digging and excavating soil, rocks, and other materials. It is typically made of heavy-duty steel and features sharp teeth or edges on the bottom to help break through tough materials. Digging buckets come in a variety of sizes and shapes to suit different excavation needs and can be attached to a range of different types of excavators.
When it comes to construction and excavation projects, having the right equipment is essential for efficient and effective work. Two commonly used attachments for excavators are digging buckets and sorting buckets. While both serve different purposes, they offer distinct advantages depending on the nature of the job at hand.
Advantages of Digging Buckets:
1. Excavation Efficiency: Digging buckets are specifically designed to penetrate the ground quickly and efficiently. They feature sharp teeth or cutting edges that enable them to break through various types of soil, rocks, and debris. This makes them ideal for digging trenches, foundations, or any task that requires substantial earthmoving.
2. Increased Productivity: The design of digging buckets allows for larger volumes of material to be moved at once. This, in turn, helps to increase productivity by reducing the number of passes required to complete a task. With a digging bucket, operators can save time and effort, ultimately accelerating the project timeline.
3. Versatility: Digging buckets come in various sizes and configurations, allowing for versatility in different excavation tasks. They can be equipped with different teeth options or additional features like tilt rotators, enabling operators to adapt to different soil conditions or project requirements.
Advantages of Sorting Buckets:
1. Enhanced Sorting Capabilities: Sorting buckets are specifically designed for separating materials on-site. They typically feature a grid or sieve-like structure that allows smaller particles to fall through while retaining larger ones. This makes them ideal for tasks like sorting rocks, debris, or separating different materials during recycling processes.
2. Cost and Time Savings: By using a Sorting Bucket, operators can eliminate the need for manual sorting or additional equipment, which can save both time and money. The ability to separate materials directly on-site eliminates the need for separate sorting facilities, reducing transportation costs and increasing operational efficiency.
3. Environmental Benefits: Sorting buckets contribute to environmental sustainability by enabling the separation and recycling of materials. By sorting and recycling on-site, construction projects can reduce the amount of waste sent to landfills, minimize the need for new raw materials, and lower the overall carbon footprint.
Conclusion:
While digging buckets excel in excavation efficiency and productivity, sorting buckets offer advantages in material separation, cost savings, and environmental sustainability. The choice between the two attachments depends on the specific requirements of the project and the desired outcomes. By understanding the advantages of each, construction professionals can make informed decisions and optimize their excavation processes.
Excavator Digging Bucket,24 Digging Bucket,600Mm Digging Bucket,Cat Digging Bucket
CATSU Hydraulic Machinery Equipment Co.,Ltd , https://www.tiltrotatorcatsu.com