R22, R407, R134A Refrigerant for Air Cooled Scroll Chiller /Industrial /Commercial Water Chiller

  • Model NO.: KDE-15A
  • Cooling Method: Air-cooled
  • Selected Voltage: 380V/440V
  • Noise Level: Low
  • Application Machine: Combination machine
  • Condition: New
  • Evaporator: Shell and Tube
  • Application: Plastic Field, Chemical, Medicine, etc
  • Trademark: JECICOOL
  • Origin: China
  • Type: Air-Cooled
  • Unit Structure: Integral
  • Compressor Number: 2
  • Application Fields: Printing
  • Certification: ISO, CE
  • Condenser: Efficient Air Cooling Type Internal Thread Copper
  • Refrigerant: R22, R407, R134A Can Be Supplied on Request
  • Fan: Low Noise Outer Fan
  • Transport Package: Wooden Case
  • HS Code: 8418692090
Air-cooling industrial chiller using advanced production technology, superior quality, compact structure, beautiful appearance. The products can be widely used in plastics, electroplating, electronics manufacturing, pharmaceutical chemicals, food processing, laser, ultrasonic cool, printing and other industries, can accurately control the demand for modern industrial mechanized production of temperature, thus greatly improving the production efficiency and product quality.

 Main Features

1. Using SANYO/Darkin from Japan, COPELAND from the United States and other brand compressors, low noise and power saving, More durable;
2. Adopt fin and tube condenser, cooling effect is good and stable performance;
3. Evaporator stainless steel water tank, built-in automatic water device;
4. Adopt imported pumps, stainless steel pump for customers to choose from, to prevent secondary pollution;
5. Microcomputer digital temperature controller, integrated operation, simple and practical, high control precision
6. Using box structure, CNC punch press precision machining, electrostatic power paint, elegant appearance, equipped with wheel so that easy to move;
7. Chiller Unit equipped with reverse phase lack protection, motor overload protection, high and low voltage protection, temperature protection and other security protection device, made the system more stable and secure. Small size, light weight, and compact structure


Technical Parameters:
Parameters Model KDE-12A KDE-15A KDE-20A KDE-25A KDE-30A KDE-40A
Nominal Cooling Capacity Kw/50Hz 35.6 44.6 58.3 75.3 89.6 118.2
Kw/60Hz 40.9 51.3 67 86.6 103 135.9
USRT/50Hz 10.1 12.7 16.6 21.4 25.5 33.6
USRT/60Hz 11.6 14.6 19.1 24.6 29.3 38.7
Kcal/h/50Hz 30616 38356 50138 64758 77056 101652
Kcal/h/60Hz 35174 44118 57620 74476 88580 116874
Input Power KW 11 14 18.5 22 30.8 37.6
Max Running Current A 32.3 41.3 55.4 63.2 76.8 97.5
Power 3PH 380V 50Hz(200V/220V/415V/460V50Hz/60Hz)
Refrigerant Type R22  (R134a/R407c)
Control Method  External-balanced Thermostatic Expansion Valve
Compressor Type Hermetic Scroll
Power KW 9 11.25 15 18.75 22.5 30
Condenser Type Efficient Aluminum Finned Copper Sleeve+Low Noise External Rotor Fan  
Cooling Air Flow m³/h  50Hz 12000 15000 20000 25000 30000 40000
m³/h  60Hz 16900 21100 27800 35400 42400 56200
Evaporator Type Tank with Coil   or Shell and Tube    
Tank Volume L 270 300 400 400 540 630
Chilled Water Flow m³/h  50Hz 6.1 7.7 10 13 15.4 20.3
m³/h  60Hz 7 8.8 11.5 14.9 17.7 23.4
Inlet/Outlet Pipe Dia. Inch 2" 2" 2-1/2" 2-1/2" 2-1/2" 3"
Water Pump Power KW 1.2 1.5 2.25 2.25 3.75 3.75
Lift M 20 20 20 20 20 20
Safety Protection Compressor over heating protection, over current protection, High/low voltage protection, over heating protection, flow protection, phase protection, Exhausting overheat protection, anti-freezing protection
Dimension Length mm 1580 2080 2110 2110 2300 2430
Width mm 790 780 850 850 930 1185
Height mm 1450 1650 1600 1700 1650 1710
Weight KG 510 750 850 950 1080 1360
Note 1. The above red  font parameters for special voltage model need to special order; Cooling capacity of R407C unit will be 5% lower than R22 unit
2. Nominal cooling capacity calculated according to: inlet/outlet chilled fluid temperature: 17ºC/12ºC; inlet/outlet cooling air temperature: 30ºC/35ºC
3. Working condition: The temperature range of chilled fluid is from 5ºC to 35ºC; temperature difference between inlet and outlet chilled fluid is from 3ºC to 8ºC.
4. It is better to run the chiller while the ambient temperature at or below 35ºC
5. The power distribution and wiring of the installation shall be based on the nameplate or installation instructions of the unit.  We reserve the rihgt to modify the above information whithout prior notice

Work Principle

R22, R407, R134A Refrigerant for Air Cooled Scroll Chiller /Industrial /Commercial Water Chiller

Applications

Be widely used in plastics, electroplating, electronics manufacturing, pharmaceutical chemicals, food processing, refrigeration and other industrial establishments and guesthouses, hotels, shopping malls, office buildings and other types of civil air-conditioning system.

R22, R407, R134A Refrigerant for Air Cooled Scroll Chiller /Industrial /Commercial Water Chiller




Package & Shipping

Use standard export plywood case with forklift truck feet, easy to load and unload
12-15 days to finish the production after receiving the deposit
Shipping by LCL or FCL


R22, R407, R134A Refrigerant for Air Cooled Scroll Chiller /Industrial /Commercial Water Chiller


After-sales service:

A. 12 months quality warranty since the date of delivery.
B. All extra parts for the machine can be purchased with agent price from COOLDERE.
C. 24 hours working phone call: +8613829879662, Email/ Skype/Trade manager online to support.
D. Professional technical team and sales person give you regarding troubleshooting procedures via Internet and Phone any time when needed.
E. Free and Professional Training at our Factory under the relaxed condition.


Necessary info to Quote

Coordere company have one special engineer team for design, they can make the special solution according to your working need, such as customize cooling capacity, special material for ship use, seawater, corrosive, food industry, juice and wine process and etc. Just tell us: 
A. What's your water composition? or industry
B. What's your temperature range?
C. What's your chilled water flow need?
D. What's the working ambient?
E. What voltage do you need?
1. Differing Refrigerants: R22, R407, R134a can be supplied on request
2. Special voltages: 115V 220V~240V 50 Hz or 60Hz (Single and Three Phase) are available then we can choose the right chiller for you.


Factory View:

R22, R407, R134A Refrigerant for Air Cooled Scroll Chiller /Industrial /Commercial Water Chiller
R22, R407, R134A Refrigerant for Air Cooled Scroll Chiller /Industrial /Commercial Water Chiller

R22, R407, R134A Refrigerant for Air Cooled Scroll Chiller /Industrial /Commercial Water Chiller

Metal Alloy Powder

Metal alloy powders are commonly used in thermal spray processes to coat surfaces with a protective or functional layer. These powders are typically made by combining different metal elements in specific compositions to achieve desired properties such as corrosion resistance, wear resistance, or thermal conductivity.

Some commonly used metal alloy powders for thermal spray include:

1. Nickel-based alloys: These alloys are known for their excellent corrosion resistance and high-temperature strength. They are often used in applications where resistance to oxidation and wear is required, such as in gas turbine components.

2. Cobalt-based alloys: Cobalt alloys are known for their high hardness and wear resistance. They are commonly used in applications where resistance to abrasive wear and high temperatures is required, such as in the aerospace and power generation industries.

3. Stainless steel alloys: Stainless steel alloys are used for their corrosion resistance and high-temperature strength. They are often used in applications where protection against corrosion and oxidation is required, such as in chemical processing equipment.

4. Titanium-based alloys: Titanium alloys are lightweight and have excellent corrosion resistance. They are commonly used in applications where a combination of high strength, low density, and corrosion resistance is required, such as in the aerospace industry.

These metal alloy powders can be applied using various thermal spray techniques, such as flame spraying, arc spraying, plasma spraying, or high-velocity oxygen fuel (HVOF) spraying. The specific choice of alloy powder and thermal spray process depends on the desired coating properties and the application requirements.

HVOF PTA Powder,Metal Spray Powder,Flame Spray Powder,Metal Alloy Powder

Luoyang Golden Egret Geotools Co., Ltd , https://www.hvofpowders.com

Posted on