MY-B112 Â Autoclavable Pipette (Adjustable and Fixed Volume)
Â
All MAYA pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22°C.
Fully autoclavable
 The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121°C, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
Â
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
Â
Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Manufactured from innovative material
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
Â
Features for multi-channel MicroPette plus
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
MicroPette Plus Single-channel Adjustable Volume Pipettes | |||||||
Cat No. | Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | ||
% | μl | % | μl | ||||
713111010000 | 0.1-2.5μl | 0.05μl | 2.5 | 2.50% | 0.0625 | 2.00% | 0.05 |
1.25 | 3.00% | 0.0375 | 3.00% | 0.0375 | |||
0.25 | 12.00% | 0.03 | 6.00% | 0.015 | |||
713111040000 | 0.5-10μl | 0.1μl | 10 | 1.00% | 0.1 | 0.80% | 0.08 |
5 | 1.50% | 0.075 | 1.50% | 0.075 | |||
1 |
Â
MY-B112 Â Autoclavable Pipette (Adjustable and Fixed Volume)
Â
All MAYA pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22°C.
Fully autoclavable
 The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121°C, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
Â
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
Â
Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Manufactured from innovative material
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
Â
Features for multi-channel MicroPette plus
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
MicroPette Plus Single-channel Adjustable Volume Pipettes | |||||||
Cat No. | Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | ||
% | μl | % | μl | ||||
713111010000 | 0.1-2.5μl | 0.05μl | 2.5 | 2.50% | 0.0625 | 2.00% | 0.05 |
1.25 | 3.00% | 0.0375 | 3.00% | 0.0375 | |||
0.25 | 12.00% | 0.03 | 6.00% | 0.015 | |||
713111040000 | 0.5-10μl | 0.1μl | 10 | 1.00% | 0.1 | 0.80% | 0.08 |
5 | 1.50% | 0.075 | 1.50% | 0.075 | |||
1 |
Automatic Fitting Fabrication Of Plastics
Fabricated fittings are constructed by joining sections of pipe,machined blocks, or molded fittings together to produce the desired configuration.
Components can be joined by butt or socket heat fusion, electrofusion, hot gas welding or extrusion welding techniques. It is not recommended to use either hot gas or extrusion welding for pressure service fittings since the resultant joint strength is significantly less than that of the other heat fusion joining methods.
Fabrication of Plastics designed for full pressure service are joined by heat fusion. For Hdpe/poly/polyethylene Fitting Fabrication of Plastics, Yuda RGH workshop plastic pipe fitting welders can make elbow, tee, cross and wye fittings in relevant clamps. For eliminating operator errors and increasing productivity, you can choose RGH-A series CNC Polyethylene Fabrication Machines, or Fully automatic HDPE Fusion Fittings Welder with all jaws operated hydraulically for faster welds, precision welding operation, and data logger function.
Automatic Fitting Fabrication Of Plastics,Fusion Weld Pipe Fittings,Butt Weld Pipe Fittings,Pipe Fitting Welding
WUXI MEIERTE MACHINERY TECHNOLOGY CO.,LTD , https://www.pipefusionweldings.com