Manual Flash Point Laboratory Tester for Petroleum Products (GD-261-1)

Model NO.: GD-261-1
Applicable Standards: ASTM D93, ISO2719
Test Method: Pensky Martens Closed Cup
Flash Point Tester Type: Semi-Auto
Trademark: GOLD
Transport Package: Veneer Case
Specification: ASTM D93, ISO2719
Origin: Chongqing, China (Mainland)
HS Code: 9031809090
Model NO.: GD-261-1
Applicable Standards: ASTM D93, ISO2719
Test Method: Pensky Martens Closed Cup
Flash Point Tester Type: Semi-Auto
Trademark: GOLD
Transport Package: Veneer Case
Specification: ASTM D93, ISO2719
Origin: Chongqing, China (Mainland)
HS Code: 9031809090
Flash Point Laboratory Equipment for Petroleum products (GD-261-1)


 

Introduction:
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.


I. Main technical features:
1. Single chip microcomputer control technique.LCD screen displays.English man-machine interaction interface.The heating power is continuously step-less adjustable.The rate of heating up is exact.Easy setting for parameters.
2. The LCD screen has prompting menu,prompting input operation interface¬.It shows the setted parameters,real-time temperatures and other test parameters.Press the "record"button when the flash point appears.The screen will show and reserve the flash point.
3. The structure is newly design and small.Stainless steel table-board looks clean and beautiful.It can be used as long as equipped with gas or other civilian fuels.It is easy to use and test results exact.


II. Main technical specifications:


 

Power supply AC( 220±10% )V, 50Hz.
Heating device (1) The furnace is silicon carbide material. Power is 600W
(2) The heating power is adjustable from 0 W to 600W
Heating rate Procedure A: (5~6)ºC/min, Procedure B:(1~1.5)ºC/min.
Stirring device (1)Stirring motor: BYGH101 stepping motor
(2) Driving mode: flexible shaft
(3) Shaft size: 8mm×40mm
Stirring rate Procedure A: (90~120)RPM, Procedure B: (250±10)RPM
Igniting device (1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
Temperature testing probe RTD, PT100
Ambient temperature ≤ 35ºC
Relative humidity ≤ 85%
Maximum power consumption 650W


Manual Flash Point Laboratory Tester for Petroleum Products (GD-261-1)

 

Flash Point Laboratory Equipment for Petroleum products (GD-261-1)


 

Introduction:
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.


I. Main technical features:
1. Single chip microcomputer control technique.LCD screen displays.English man-machine interaction interface.The heating power is continuously step-less adjustable.The rate of heating up is exact.Easy setting for parameters.
2. The LCD screen has prompting menu,prompting input operation interface¬.It shows the setted parameters,real-time temperatures and other test parameters.Press the "record"button when the flash point appears.The screen will show and reserve the flash point.
3. The structure is newly design and small.Stainless steel table-board looks clean and beautiful.It can be used as long as equipped with gas or other civilian fuels.It is easy to use and test results exact.


II. Main technical specifications:


 

Power supply AC( 220±10% )V, 50Hz.
Heating device (1) The furnace is silicon carbide material. Power is 600W
(2) The heating power is adjustable from 0 W to 600W
Heating rate Procedure A: (5~6)ºC/min, Procedure B:(1~1.5)ºC/min.
Stirring device (1)Stirring motor: BYGH101 stepping motor
(2) Driving mode: flexible shaft
(3) Shaft size: 8mm×40mm
Stirring rate Procedure A: (90~120)RPM, Procedure B: (250±10)RPM
Igniting device (1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
Temperature testing probe RTD, PT100
Ambient temperature ≤ 35ºC
Relative humidity ≤ 85%
Maximum power consumption 650W


Manual Flash Point Laboratory Tester for Petroleum Products (GD-261-1)

 

Power Cable

Power cable has two types called round cable and flat cable, and power cable consist of conductor, insulating layer, protective layer, barrier layer and armored layer. Power cable has different specification according to different efficiency of motor and different condition of well. And the power cable can be divided into low temperature and high temperature depends on the anti-temperature. According to voltage, there are grade of 3kV and 6kV. And the cable can use galvanized steel, stainless steel or Monel steel to avoid corrosion.

Power Cable

Power Cable,Electric Petroleum Submerged Pump Unit,Control Cabinet,Separator And Inducer

Tianjin RongHeng Group LLC , https://www.ronghenggrouppump.com

Posted on